Tag read
No tag yet — connect, then hold an FDX-B (134.2 kHz) tag within 14 cm of the reader
Country code (Country ID · 10 bit)
—
Tag number (National ID · 38 bit)
—
Frame number (increments on every read)
—
Raw 8 bytes (registers 06–09)
—
Every bit of the tag (decoded from the 8 bytes)
| — no tag yet — |
This reader reads standard FDX-B animal tags (ISO 11784/11785) at 134.2 kHz — not the Mifare cards of the 501/401 · a tag holds only its code and cannot be rewritten · the frame number changes on every successful read, so you can tell a repeated read of the same tag from a tag that left the range
Codes are shown in decimal (the same format printed on the tag, e.g. 764 000123456789) · a blank card (EM4305) must first be written on the Tag writer
Codes are shown in decimal (the same format printed on the tag, e.g. 764 000123456789) · a blank card (EM4305) must first be written on the Tag writer
3D view of the reader
Blue ABS housing 173 × 66 × 31 mm (body 160 · mounting 136 × 42 · 4 × ø9.5 holes), M12 connector at the rear · IP67 · whenever a tag is read it floats in with its code · the green rings are the 14 cm read range from the spec · mount so that reader→drive-wheel distance L and wheel spacing D give L/D ≈ 1.5
Drag to orbit · scroll to zoom · double-click to reset the view
Drag to orbit · scroll to zoom · double-click to reset the view
Which reader to talk to
| Operating mode | — |
|---|---|
| Frame-number refresh interval | — |
| CAN ID · CAN baud | — |
| Manufacture date (register 13H) | — |
⚠️ The unit tested (23 Sep) arrived as ID 0 · 4800 · mode 0 (since reset to ID 1 · 115200) — if it does not reply, press "Find reader" to scan · manual defaults: ID 1 · 115200 8N1 · CAN ID 0x161 · CAN 500 kbps · connect via RS-485 (pin 5 white = A · 6 grey = B) or RS-232 (pin 3 green = reader TX → adapter RX · pin 4 brown = RX) · 9–28 V supply (pin 1 red + · 2 black −)
Change settings in the reader
This page usesmode 2 (polled) — if the reader is in mode 0/1 it also pushes data by itself; this page accepts both · on the real robot the controller usually uses mode 0 (continuous auto-report)
Baud code table for this model: 0=4800 1=9600 2=14400 3=38400 5=56000 6=57600 7=115200 8=128000 9=256000 (there is no code 4)
Baud code table for this model: 0=4800 1=9600 2=14400 3=38400 5=56000 6=57600 7=115200 8=128000 9=256000 (there is no code 4)
🔴 After changing the ID/baud you must reconnect with the new values and update the AGV-side program too · the manual says to power-cycle the reader after configuring
Cable and connector (M12 · 8 pin · 1 m RVVP cable)
| Pin | Colour | Signal | Connect to |
|---|---|---|---|
| 1 | Red | VCC | 9–28 V supply + |
| 2 | Black | GND | Supply − and adapter GND |
| 3 | Green | 232-TX | RXD of the RS-232 adapter |
| 4 | Brown | 232-RX | TXD of the RS-232 adapter |
| 5 | White | 485-A | A of the RS-485 adapter |
| 6 | Grey | 485-B | B of the RS-485 adapter |
| 7 | Blue | CAN-H | Robot controller CAN (500 kbps · ID 0x161) |
| 8 | Yellow | CAN-L |
Wiring RS-232 and RS-485 at the same time gains nothing — pick one · no metal between reader and tag · maximum read speed 3 m/s
Communication log
This model uses Modbus RTU (RS-232 or RS-485 · 115200 8N1) and readsFDX-B 134.2 kHz animal tags not Mifare cards — registers 06–09 hold the tag code (10-bit country + 38-bit national ID + frame number)
Example frames from the manual: read tag
Example frames from the manual: read tag
01 03 00 06 00 04 A4 08 · set polled mode 01 06 00 04 00 02 49 CA — the tool builds them byte-for-byte · 🔴 not yet tested with a real reader · CAN is also supported (ID 0x161 · 500 kbps) but this page uses the serial port